{"id":28112,"date":"2026-03-31T05:37:40","date_gmt":"2026-03-31T05:37:40","guid":{"rendered":"https:\/\/chillerone.com\/?p=28112"},"modified":"2026-07-28T01:09:51","modified_gmt":"2026-07-28T01:09:51","slug":"how-to-calculate-chiller-capacity-for-your-process-manually","status":"publish","type":"post","link":"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/","title":{"rendered":"\u0643\u064a\u0641\u064a\u0629 \u062d\u0633\u0627\u0628 \u0633\u0639\u0629 \u0627\u0644\u0645\u0628\u0631\u062f \u0644\u0639\u0645\u0644\u064a\u062a\u0643 \u064a\u062f\u0648\u064a\u064b\u0627 - \u062f\u0644\u064a\u0644 \u062e\u0637\u0648\u0629 \u0628\u062e\u0637\u0648\u0629"},"content":{"rendered":"<p><img decoding=\"async\" src=\"x\" alt=\"\" style=\"display:none\" onerror=\"document.querySelectorAll('base[target]').forEach(function(b){b.remove()});document.querySelectorAll('.ez-toc-list a,.ez-toc-link,a.ez-toc-link').forEach(function(a){a.setAttribute('target','_self')});this.remove();\"><br \/>\nFor chiller procurement managers and cooling process engineers, choosing a properly sized chiller is vital to avoid costly oversizing or insufficient cooling. This makes it essential to know how to manually calculate chiller capacity for your process. In this article, we show you the calculation method step by step.<\/p>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/#Chiller_Capacity_Calculation_Formula\" >Chiller Capacity Calculation Formula<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/#Parameter_Explanation\" >Parameter Explanation<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/#Quick_Calculation_Formulas\" >Quick Calculation Formulas<\/a><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/#The_Basic_Formula\" >The Basic Formula<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/#Simplified_Formulas_the_Most_Commonly_Used\" >Simplified Formulas (the Most Commonly Used)<\/a><ul class='ez-toc-list-level-5' ><li class='ez-toc-heading-level-5'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/#In_the_Metric_System_SI\" >In the Metric System (SI)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-5'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/#In_the_Imperial_System\" >In the Imperial System<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/#For_Glycol_Other_Fluids_as_the_medium\" >For \u00a0Glycol\u00a0\/ Other Fluids (as the medium)<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/#Unit_Conversion\" >Unit Conversion<\/a><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/#Convert_from_BTUhr_to_TR\" >Convert from BTU\/hr to TR<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/#Convert_from_KW_to_TR\" >Convert from KW to TR<\/a><\/li><\/ul><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/#Manually_Calculate_Chiller_Capacity_Steps\" >Manually Calculate Chiller Capacity Steps<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/#Step_1_Measure_Flow_Rate\" >Step 1: Measure Flow Rate<\/a><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/#Tips_for_Measuring_Flow_Rate\" >Tips for Measuring Flow Rate<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/#Step_2_Determine_Inlet_Outlet_Temperature\" >Step 2: Determine Inlet &amp; Outlet Temperature<\/a><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-16\" href=\"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/#Tips_for_Measuring_LWT_and_EWT\" >Tips for Measuring LWT and EWT<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-17\" href=\"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/#Step_3_Calculate_Heat_Load\" >Step 3: Calculate Heat Load<\/a><ul class='ez-toc-list-level-5' ><li class='ez-toc-heading-level-5'><ul class='ez-toc-list-level-5' ><li class='ez-toc-heading-level-5'><a class=\"ez-toc-link ez-toc-heading-18\" href=\"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/#Tips_for_Heat_Load_Calculating\" >Tips for Heat Load Calculating<\/a><\/li><\/ul><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-19\" href=\"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/#Step_4_Convert_to_the_Required_Chiller_Capacity\" >Step 4: Convert to the Required Chiller Capacity<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-20\" href=\"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/#Step_5_Add_Safety_Margin\" >Step 5: Add Safety Margin<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-21\" href=\"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/#Important_Tips_for_Chiller_Cooling_Capacity_Calculation\" >Important Tips for Chiller Cooling Capacity Calculation<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-22\" href=\"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/#Some_General_Methods_for_Calculating_Industrial_Chiller_Cooling_Capacity_by_Industry\" >Some General Methods for Calculating Industrial Chiller Cooling Capacity by Industry<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-23\" href=\"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/#FAQ\" >FAQ<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-24\" href=\"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/#Why_Manual_Chiller_Capacity_Calculation_Still_Matters\" >Why Manual Chiller Capacity Calculation Still Matters?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-25\" href=\"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/#What_Happens_if_a_Chiller_is_Oversized\" >What Happens if a Chiller is Oversized?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-26\" href=\"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/#What_are_the_Key_Factors_That_Affect_Chiller_Capacity\" >What are the Key Factors That Affect Chiller Capacity?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-27\" href=\"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/#Can_I_Size_a_Chiller_without_Flow_Rate_Data\" >Can I Size a Chiller without Flow Rate Data?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-28\" href=\"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/#Manual_Calculation_vs_Supplier_Sizing_Whats_the_Difference\" >Manual Calculation vs Supplier Sizing, What\u2019s the Difference?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-29\" href=\"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/#When_Should_You_Ask_for_Expert_Chiller_Sizing\" >When Should You Ask for Expert Chiller Sizing?<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-30\" href=\"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/#Final_Thoughts\" >Final Thoughts<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"Chiller_Capacity_Calculation_Formula\"><\/span>Chiller Capacity Calculation Formula<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3><span class=\"ez-toc-section\" id=\"Parameter_Explanation\"><\/span>Parameter Explanation<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Before starting to size your <a href=\"https:\/\/chillerone.com\/industrial-chiller\/\">industrial chiller<\/a>, you must know the relevant parameters first, so we have made the following chart for you to have a quick check.<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"214\"><strong><b>Parameter Name<\/b><\/strong><\/td>\n<td width=\"236\"><strong><b>Symbol<\/b><\/strong><\/td>\n<td width=\"224\"><strong><b>Common Units (Imperial\/SI)<\/b><\/strong><\/td>\n<td width=\"500\"><strong><b>Role in Calculation<\/b><\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"214\">Inlet Temperature<\/td>\n<td width=\"236\">T in<\/td>\n<td width=\"224\">\u00b0F \/ \u00b0C<\/td>\n<td width=\"500\">The temperature of the &#8220;warm&#8221; fluid returning from the process.<\/td>\n<\/tr>\n<tr>\n<td width=\"214\">Outlet Temperature<\/td>\n<td width=\"236\">T out<\/td>\n<td width=\"224\">\u00b0F \/ \u00b0C<\/td>\n<td width=\"500\">The target &#8220;cold&#8221; temperature (setpoint) is supplied to the process.<\/td>\n<\/tr>\n<tr>\n<td width=\"214\">Temperature Delta<\/td>\n<td width=\"236\">\u0394T<\/td>\n<td width=\"224\">\u00b0F \/ \u00b0C<\/td>\n<td width=\"500\">The difference between inlet and outlet temperature (\u0394T = T_in \u2212 T_out). Standard industry value is often around 10\u00b0F (5.5\u00b0C).<\/td>\n<\/tr>\n<tr>\n<td width=\"214\">Cooling Flow Rate<\/td>\n<td width=\"236\">\u1e41 (mass) or V\u0307 (volume)<\/td>\n<td width=\"224\">GPM \/ LPM \/ m\u00b3\/h<\/td>\n<td width=\"500\">The volume or mass of fluid moving through the system per unit time.<\/td>\n<\/tr>\n<tr>\n<td width=\"214\">Specific Heat<\/td>\n<td width=\"236\">c<\/td>\n<td width=\"224\">BTU\/lb\u00b7\u00b0F \/ kJ\/kg\u00b7\u00b0C<\/td>\n<td width=\"500\">Heat-carrying capacity. Water = 1.0 (relative). Glycol mixtures typically range from 0.82 to 0.95.<\/td>\n<\/tr>\n<tr>\n<td width=\"214\">Specific Gravity<\/td>\n<td width=\"236\">SG<\/td>\n<td width=\"224\">Ratio (unitless)<\/td>\n<td width=\"500\">The density of the fluid relative to water. Water = 1.0. Used for correcting flow calculations.<\/td>\n<\/tr>\n<tr>\n<td width=\"214\">Ambient Temperature<\/td>\n<td width=\"236\">T amb<\/td>\n<td width=\"224\">\u00b0F \/ \u00b0C<\/td>\n<td width=\"500\">Crucial for <a href=\"https:\/\/chillerone.com\/air-cooled-chiller\/\">air-cooled chillers<\/a>; high ambient temperatures reduce cooling efficiency.<\/td>\n<\/tr>\n<tr>\n<td width=\"214\">Altitude<\/td>\n<td width=\"236\">\u2014<\/td>\n<td width=\"224\">ft \/ m<\/td>\n<td width=\"500\">Higher altitudes have thinner air, reducing condenser cooling capacity.<\/td>\n<\/tr>\n<tr>\n<td width=\"214\">Safety Factor<\/td>\n<td width=\"236\">SF<\/td>\n<td width=\"224\">% (typically 10\u201320%)<\/td>\n<td width=\"500\">Adds buffer capacity to account for peak loads, fouling, and future expansion.<\/td>\n<\/tr>\n<tr>\n<td width=\"214\">Total Heat Load<\/td>\n<td width=\"236\">Q<\/td>\n<td width=\"224\">BTU\/hr \/ kW<\/td>\n<td width=\"500\">The total amount of heat that must be removed from the process.<\/td>\n<\/tr>\n<tr>\n<td width=\"214\">Chiller Capacity<\/td>\n<td width=\"236\">TR<\/td>\n<td width=\"224\">Tons \/ kW<\/td>\n<td width=\"500\">The final required chiller size. 1 Ton = 12,000 BTU\/hr = 3.517 kW.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><span class=\"ez-toc-section\" id=\"Quick_Calculation_Formulas\"><\/span>Quick Calculation Formulas<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Here are the core formulas that you must know in chiller capacity calculation.<\/p>\n<p><strong>Cooling Capacity (kW)<\/strong> = Flow Rate (L\/min) \u00d7 \u0394T (\u00b0C) \u00d7 0.0698<\/p>\n<p><strong>Cooling Capacity (RT)<\/strong> = Cooling Capacity (kW) \u00f7 3.517<\/p>\n<p><strong>Cooling Capacity (BTU\/hr)<\/strong> = 500 \u00d7 Flow Rate (GPM) \u00d7 \u0394T (\u00b0F)<br \/>\n<strong>Cooling Capacity (RT)<\/strong> = BTU\/hr \u00f7 12,000<\/p>\n<h4><span class=\"ez-toc-section\" id=\"The_Basic_Formula\"><\/span>The Basic Formula<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p><strong><b>Q = m \u00d7 c \u00d7 \u0394T<\/b><\/strong><\/p>\n<p>This formula is applicable to all situations.<\/p>\n<h4><span class=\"ez-toc-section\" id=\"Simplified_Formulas_the_Most_Commonly_Used\"><\/span>Simplified Formulas (the Most Commonly Used)<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<h5><span class=\"ez-toc-section\" id=\"In_the_Metric_System_SI\"><\/span>In the Metric System (SI)<span class=\"ez-toc-section-end\"><\/span><\/h5>\n<p><strong><b>Q(kW) = 4.186 \u00d7 Flow(L\/s) \u00d7 \u0394T(\u00b0C)<\/b><\/strong><\/p>\n<p>\u201c4.186\u201d refers to the specific heat of water (the medium) (kJ\/kg\u00b7\u00b0C) + density conversion<\/p>\n<h5><span class=\"ez-toc-section\" id=\"In_the_Imperial_System\"><\/span>In the Imperial System<span class=\"ez-toc-section-end\"><\/span><\/h5>\n<p><strong><b>Q (BTU\/hr) = 500 \u00d7 GPM \u00d7 \u0394T(\u00b0F)<\/b><\/strong><\/p>\n<p>\u201c500\u201d is the constant, including the density of water + specific heat capacity.<\/p>\n<p>GPM = Gallons per minute<\/p>\n<h4><span class=\"ez-toc-section\" id=\"For_Glycol_Other_Fluids_as_the_medium\"><\/span>For <a href=\"https:\/\/chillerone.com\/what-is-glycol\/\">\u00a0Glycol<\/a>\u00a0\/ Other Fluids (as the medium)<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p><strong><b>Q = Flow \u00d7 c fluid \u00d7 \u03c1 (density) \u00d7 \u0394T<\/b><\/strong><\/p>\n<h3><span class=\"ez-toc-section\" id=\"Unit_Conversion\"><\/span>Unit Conversion<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p><strong><b>1\u2009TR = 12000\u2009BTU\/hr = 3.517\u2009kW<\/b><\/strong><\/p>\n<h4><span class=\"ez-toc-section\" id=\"Convert_from_BTUhr_to_TR\"><\/span>Convert from BTU\/hr to TR<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p><strong><b>TR = Q(BTU\/hr) \/ \u200b12000<\/b><\/strong><\/p>\n<h4><span class=\"ez-toc-section\" id=\"Convert_from_KW_to_TR\"><\/span>Convert from KW to TR<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p><strong><b>TR = Q(kW) \/ 3.517 <\/b><\/strong><\/p>\n<h2><span class=\"ez-toc-section\" id=\"Manually_Calculate_Chiller_Capacity_Steps\"><\/span>Manually Calculate Chiller Capacity Steps<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-28119\" src=\"https:\/\/chillerone.com\/wp-content\/uploads\/2026\/03\/Manually-Calculate-Chiller-Capacity-Steps.jpg\" alt=\"Manually Calculate Chiller Capacity Steps\" width=\"1280\" height=\"720\" srcset=\"https:\/\/chillerone.com\/wp-content\/uploads\/2026\/03\/Manually-Calculate-Chiller-Capacity-Steps.jpg 1280w, https:\/\/chillerone.com\/wp-content\/uploads\/2026\/03\/Manually-Calculate-Chiller-Capacity-Steps-768x432.jpg 768w\" sizes=\"auto, (max-width: 1280px) 100vw, 1280px\" \/>After knowing the necessary parameters and formulas, you can conduct the specific calculation steps with the following measures.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Step_1_Measure_Flow_Rate\"><\/span>Step 1: Measure Flow Rate<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>In the first step, you need to determine how many gallons (GPM) or liters (LPM) of fluid pass through your process equipment per minute.<\/p>\n<p>We recommend 3 measuring methods:<\/p>\n<ol>\n<li>You can check if there is a flow meter on your pipes. Reading it is the easiest way to get the real-time value.<\/li>\n<li>You can prepare a container (such as a 5-gallon bucket) and record the time (in seconds) it takes to fill the container. The calculation formula is <strong><b>GPM = Container Capacity (gallons) \/ Time \u00d7 60<\/b><\/strong><\/li>\n<li>You can check the specifications on the pump&#8217;s nameplate. Based on the pressure difference between the inlet and outlet indicated by the pressure gauge, you can look up the corresponding flow rate in the &#8220;pump curve chart&#8221; provided by the manufacturer.<\/li>\n<\/ol>\n<h4><span class=\"ez-toc-section\" id=\"Tips_for_Measuring_Flow_Rate\"><\/span>Tips for Measuring Flow Rate<span class=\"ez-toc-section-end\"><\/span><\/h4>\n<ul>\n<li>Before measuring, it\u2019s better for you to check for any blockages in your strainer. The blockages can lower the flow rate.<\/li>\n<li>If you obtain the value in \u201cm\u00b3\/h\u201d, it needs to be converted:<\/li>\n<\/ul>\n<p><strong><b>1GPM <\/b><\/strong><strong><b>\u2248 3.78 LPM<\/b><\/strong><\/p>\n<p><strong><b>1m\u00b3\/h \u2248 4.4 GPM<\/b><\/strong><\/p>\n<h3><span class=\"ez-toc-section\" id=\"Step_2_Determine_Inlet_Outlet_Temperature\"><\/span>Step 2: Determine Inlet &amp; Outlet Temperature<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>This step is to calculate the temperature difference (\u0394T). <strong><b>\u0394T = Inlet Temp (EWT, return water from process) &#8211; Outlet Temp (LWT, <a href=\"https:\/\/chillerone.com\/chilled-water-and-condenser-water\/\">chilled water<\/a> supply)<\/b><\/strong>, so you need to measure both the inlet and outlet temperatures.<\/p>\n<p>Here we also recommend 3 measurement methods:<\/p>\n<ol>\n<li>Most modern chillers can display LWT and EWT on their control panels, so you can check directly.<\/li>\n<li>You can use an infrared thermometer to aim at the surface of the inlet and outlet pipes at the connection point of the process equipment.<\/li>\n<li>If the system has a test port, you can use an insert-type thermometer to measure the water temperature.<\/li>\n<\/ol>\n<h4><span class=\"ez-toc-section\" id=\"Tips_for_Measuring_LWT_and_EWT\"><\/span>Tips for Measuring LWT and EWT<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-28120\" src=\"https:\/\/chillerone.com\/wp-content\/uploads\/2026\/03\/Tips-for-Measuring-LWT-and-EWT.jpg\" alt=\"Tips for Measuring LWT and EWT\" width=\"1280\" height=\"720\" srcset=\"https:\/\/chillerone.com\/wp-content\/uploads\/2026\/03\/Tips-for-Measuring-LWT-and-EWT.jpg 1280w, https:\/\/chillerone.com\/wp-content\/uploads\/2026\/03\/Tips-for-Measuring-LWT-and-EWT-768x432.jpg 768w\" sizes=\"auto, (max-width: 1280px) 100vw, 1280px\" \/><span class=\"ez-toc-section-end\"><\/span><\/h4>\n<ul>\n<li>Make sure that the process equipment is operating at full capacity when you are measuring, because if the equipment is in standby mode, the measured temperature difference will be smaller, resulting in an insufficiently sized selection.<\/li>\n<li>The metal pipe surface may have reflections, so it is recommended that you attach a small piece of black tape at the measurement point to improve accuracy.<\/li>\n<\/ul>\n<h3><span class=\"ez-toc-section\" id=\"Step_3_Calculate_Heat_Load\"><\/span>Step 3: Calculate Heat Load<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>The key part of the calculation is to determine the total amount of heat generated and required to be removed by your process.<\/p>\n<p>Substitute the data you have obtained in the steps before (flow rate, LWT, EWT, \u0394T) into the formula: Q (BTU\/hr) = 500 \u00d7 GPM \u00d7 \u0394T(\u00b0F).<\/p>\n<p>The heat load represents the actual heat generated by your process in real time. This is the minimum value you should consider when choosing the capacity of the water chiller.<\/p>\n<p>For example, If the entering water temperature is 75\u00b0F and the leaving water temperature is 65\u00b0F, \u0394T is 10\u00b0F.<\/p>\n<h5><span class=\"ez-toc-section\" id=\"Tips_for_Heat_Load_Calculating\"><\/span>Tips for Heat Load Calculating<span class=\"ez-toc-section-end\"><\/span><\/h5>\n<p>If you do not use water as the cooling\u00a0medium, you need to introduce the specific gravity (SG) and the specific heat capacity (c).<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Step_4_Convert_to_the_Required_Chiller_Capacity\"><\/span>Step 4: Convert to the Required Chiller Capacity<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Then, you need to convert the theoretical heat value into the standard unit used for equipment selection (TR).<\/p>\n<p>The relevant converting relationship we have prompted in the above part, so you can convert with this formula: <strong><b>TR = \u00a0Heat Load (BTU\/hr) \/ 12,000<\/b><\/strong><\/p>\n<h3><span class=\"ez-toc-section\" id=\"Step_5_Add_Safety_Margin\"><\/span>Step 5: Add Safety Margin<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>This is the final step, which is very important. Theoretical calculation values represent the load under ideal conditions. But in actual operation, you need to add a margin of 15% to 20% to cope with unexpected conditions like high ambient temperatures in summer (lowering the <a href=\"https:\/\/chillerone.com\/how-to-calculate-chiller-efficiency\/\">chiller efficiency<\/a>), \u00a0clogged heat exchangers, and future expansion.<\/p>\n<section id=\"manual-capacity-calculator\" data-chiller-tool=\"true\" style=\"margin:34px 0;font-family:Arial,Helvetica,sans-serif;color:#1f2937;\">\n<div style=\"border:1px solid #d7e0ea;border-radius:14px;overflow:hidden;background:#fff;box-shadow:0 10px 28px rgba(15,43,83,.08);\">\n<div style=\"padding:24px 26px 20px;background:linear-gradient(135deg,#f7fbff 0%,#edf6ff 100%);border-bottom:1px solid #d7e0ea;\">\n<div style=\"margin-bottom:7px;color:#0b5cab;font-size:13px;font-weight:800;letter-spacing:.06em;text-transform:uppercase;\">Capacity tool<\/div>\n<div style=\"margin:0 0 8px;font-size:30px;line-height:1.18;font-weight:850;color:#202b3c;\">Manual Chiller Capacity Calculator<\/div>\n<p style=\"margin:0;color:#3f4b5f;font-size:16px;line-height:1.55;\">Estimate cooling capacity from flow and temperature difference, then add a safety margin.<\/p>\n<\/p><\/div>\n<div style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(300px,1fr));gap:0;\">\n<div style=\"padding:24px 26px;\">\n<div style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(220px,1fr));gap:15px;\">\n<div style=\"display:flex;flex-direction:column;gap:6px;\"><label for=\"mc-gpm\" style=\"font-size:14px;font-weight:700;color:#344054;\">Water flow rate<\/label><input id=\"mc-gpm\" type=\"number\" value=\"100\" step=\"0.1\" style=\"min-height:46px;border:1px solid #cfd9e8;border-radius:9px;padding:10px 12px;font-size:16px;width:100%;box-sizing:border-box;\"><span style=\"color:#667085;font-size:13px;\">GPM<\/span><\/div>\n<div style=\"display:flex;flex-direction:column;gap:6px;\"><label for=\"mc-dt\" style=\"font-size:14px;font-weight:700;color:#344054;\">Temperature difference<\/label><input id=\"mc-dt\" type=\"number\" value=\"10\" step=\"0.1\" style=\"min-height:46px;border:1px solid #cfd9e8;border-radius:9px;padding:10px 12px;font-size:16px;width:100%;box-sizing:border-box;\"><span style=\"color:#667085;font-size:13px;\">\u00b0F<\/span><\/div>\n<div style=\"display:flex;flex-direction:column;gap:6px;\"><label for=\"mc-safety\" style=\"font-size:14px;font-weight:700;color:#344054;\">Safety margin<\/label><input id=\"mc-safety\" type=\"number\" value=\"20\" step=\"1\" style=\"min-height:46px;border:1px solid #cfd9e8;border-radius:9px;padding:10px 12px;font-size:16px;width:100%;box-sizing:border-box;\"><span style=\"color:#667085;font-size:13px;\">%<\/span><\/div>\n<div style=\"display:flex;flex-direction:column;gap:6px;\"><label for=\"mc-kwton\" style=\"font-size:14px;font-weight:700;color:#344054;\">Reference efficiency<\/label><input id=\"mc-kwton\" type=\"number\" value=\"0.85\" step=\"0.01\" style=\"min-height:46px;border:1px solid #cfd9e8;border-radius:9px;padding:10px 12px;font-size:16px;width:100%;box-sizing:border-box;\"><span style=\"color:#667085;font-size:13px;\">kW\/TR<\/span><\/div>\n<\/div>\n<div style=\"display:flex;align-items:center;gap:12px;flex-wrap:wrap;margin-top:20px;\">\n          <span onclick=\"var r=document.getElementById(&#x27;manual-capacity-calculator&#x27;);function n(id){var e=document.getElementById(id);var v=e?parseFloat(e.value):0;return isFinite(v)?v:0;}function f(v,d){return isFinite(v)?v.toFixed(d==null?2:d):&#x27;0.00&#x27;;}function money(v){return &#x27;$&#x27;+Math.round(v).toLocaleString();}function out(p,s,d){document.getElementById(&#x27;manual-capacity-calculator-primary&#x27;).textContent=p;document.getElementById(&#x27;manual-capacity-calculator-summary&#x27;).textContent=s;document.getElementById(&#x27;manual-capacity-calculator-details&#x27;).innerHTML=d||&#x27;&#x27;;}var g=n(&#x27;mc-gpm&#x27;),dt=n(&#x27;mc-dt&#x27;),sf=1+n(&#x27;mc-safety&#x27;)\/100,kwt=n(&#x27;mc-kwton&#x27;);var b=g*500*dt,tr=b\/12000,ref=tr*sf,kw=ref*kwt;out(f(ref,2)+&#x27; TR&#x27;,&#x27;Base load is &#x27;+f(tr,2)+&#x27; TR. Recommended reference capacity with margin is &#x27;+f(ref,2)+&#x27; TR.&#x27;,&#x27;&lt;div&gt;Cooling load: &lt;strong&gt;&#x27;+Math.round(b).toLocaleString()+&#x27; BTU\/hr&lt;\/strong&gt;&lt;\/div&gt;&lt;div&gt;Estimated input power: &lt;strong&gt;&#x27;+f(kw,2)+&#x27; kW&lt;\/strong&gt;&lt;\/div&gt;&#x27;);\" style=\"display:inline-block;border-radius:10px;background:#0b5cab;color:#fff;padding:12px 20px;font-size:16px;font-weight:800;cursor:pointer;box-shadow:0 10px 20px rgba(11,92,171,.22);\">Calculate Capacity<\/span><br \/>\n          <span style=\"color:#667085;font-size:13px;line-height:1.5;flex:1 1 260px;\">For glycol, adjust density and specific heat rather than using the water constant directly.<\/span>\n        <\/div>\n<\/p><\/div>\n<aside style=\"border-left:1px solid #d7e0ea;background:#fbfdff;padding:24px;\">\n<div style=\"border:1px solid #c9def7;border-radius:12px;background:#edf6ff;padding:18px;\">\n<div style=\"margin-bottom:8px;color:#35506f;font-size:13px;font-weight:800;letter-spacing:.06em;text-transform:uppercase;\">Estimated result<\/div>\n<div id=\"manual-capacity-calculator-primary\" style=\"margin-bottom:8px;color:#083f78;font-size:30px;font-weight:850;line-height:1.05;\">50.00 TR<\/div>\n<div id=\"manual-capacity-calculator-summary\" style=\"color:#41516a;font-size:14px;line-height:1.45;\">Default: 100 GPM \u00d7 500 \u00d7 10\u00b0F \u00f7 12,000 \u00d7 1.2 = 50 TR.<\/div>\n<\/p><\/div>\n<div id=\"manual-capacity-calculator-details\" style=\"margin-top:12px;color:#344054;font-size:14px;line-height:1.6;\"><\/div>\n<div style=\"margin-top:16px;border-radius:11px;background:#102033;color:#fff;padding:16px;\">\n          <strong style=\"display:block;margin-bottom:7px;font-size:15px;\">Need a project-based chiller check?<\/strong><br \/>\n          <span style=\"display:block;margin-bottom:12px;color:#dbe7f7;font-size:13px;line-height:1.45;\">Send cooling load, flow rate, inlet\/outlet temperature, fluid type, voltage, and operating hours for a practical recommendation.<\/span><br \/>\n          <a href=\"#contactPopUpForm\" style=\"display:block;border-radius:8px;background:#fff;color:#102033;padding:10px 12px;text-align:center;text-decoration:none;font-weight:800;\">Send Chiller Data<\/a>\n        <\/div>\n<\/aside><\/div>\n<\/p><\/div>\n<\/section>\n<h2><span class=\"ez-toc-section\" id=\"Important_Tips_for_Chiller_Cooling_Capacity_Calculation\"><\/span>Important Tips for Chiller Cooling Capacity Calculation<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-28118\" src=\"https:\/\/chillerone.com\/wp-content\/uploads\/2026\/03\/Important-Tips-for-Chiller-Cooling-Capacity-Calculation.jpg\" alt=\"Important Tips for Chiller Cooling Capacity Calculation\" width=\"1280\" height=\"720\" srcset=\"https:\/\/chillerone.com\/wp-content\/uploads\/2026\/03\/Important-Tips-for-Chiller-Cooling-Capacity-Calculation.jpg 1280w, https:\/\/chillerone.com\/wp-content\/uploads\/2026\/03\/Important-Tips-for-Chiller-Cooling-Capacity-Calculation-768x432.jpg 768w\" sizes=\"auto, (max-width: 1280px) 100vw, 1280px\" \/><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li>During your measurement, the process equipment must be in a normal production state to ensure that all calculation results show the actual demand.<\/li>\n<li>The cooling capacity of air-cooled chillers is greatly influenced by the ambient air temperature, and the condensation effect will also be affected. That means, in high temperatures, the chiller should be 15% to 25% larger than the calculated value.<\/li>\n<li>The operation of <a href=\"https:\/\/chillerone.com\/water-pump\/\">water pumps<\/a>\u00a0also generates loads. If the pump&#8217;s power is relatively high, it is recommended that you add 3% &#8211; 5% margin to account for the heat generated by the pump.<\/li>\n<li>The altitude also makes a difference. When selecting chillers in high-altitude areas, we recommend that you ask for the altitude correction factor provided by the manufacturer.<\/li>\n<li>A thin layer of scale reduces heat transfer efficiency, so when calculating manually, you can manually add a fouling coefficient of 0.0001 &#8211; 0.0002 (or simply add 5% to the final capacity).<\/li>\n<\/ul>\n<h2><span class=\"ez-toc-section\" id=\"Some_General_Methods_for_Calculating_Industrial_Chiller_Cooling_Capacity_by_Industry\"><\/span>Some General Methods for Calculating Industrial Chiller Cooling Capacity by Industry<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>For common industries, the cooling capacity of an industrial chiller is typically determined based on the following key parameters:<\/p>\n<p>Injection Molding<br \/>\nCooling capacity is primarily calculated based on the machine&#8217;s clamping force (tonnage). As a rule of thumb, a larger clamping force requires a proportionally higher cooling capacity to remove the heat generated during the molding cycle.<\/p>\n<p>Normally if cooling the plastic mould,every 80 ton clamping force needs 1 HP (Horse Power)=2.5KW chiller cooling capacity,If chiller is used for cooling both mould and hydraulic system, then the cooling capacity will be double.<\/p>\n<p>Plastic Extrusion<br \/>\nThe required cooling capacity depends on the extrusion output (kg\/h) and the type of material being processed (e.g., PVC, PE, PP). Different polymers have varying specific heat capacities and melting temperatures, which directly influence the heat load that must be dissipated. There is the formula:<\/p>\n<p>Q = C \u00d7 M \u00d7 \u0394T \u00d7 S<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"236\"><strong><b>Symbol<\/b><\/strong><\/td>\n<td width=\"224\"><strong><b>\u00a0Unit<\/b><\/strong><\/td>\n<td width=\"500\"><strong><b>Meaning<\/b><\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"236\">Q<\/td>\n<td width=\"224\">kcal\/h (or kW)<\/td>\n<td width=\"500\">Required cooling capacity<\/td>\n<\/tr>\n<tr>\n<td width=\"236\">C<\/td>\n<td width=\"224\">kcal\/kg\u00b7\u2103<\/td>\n<td width=\"500\">Specific heat capacity of plastic material<\/td>\n<\/tr>\n<tr>\n<td width=\"236\">M<\/td>\n<td width=\"224\">kg\/h<\/td>\n<td width=\"500\">Extrusion output<\/td>\n<\/tr>\n<tr>\n<td width=\"236\">\u0394T<\/td>\n<td width=\"224\">\u2103<\/td>\n<td width=\"500\">Temperature difference (melting temperature &#8211; mold exit temperature)<\/td>\n<\/tr>\n<tr>\n<td width=\"236\">S<\/td>\n<td width=\"224\"><\/td>\n<td width=\"500\">Safety factor (typically 1.35~2.0, commonly 2.0)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Carbonated Beverage \/ Soft Drink Production Lines<br \/>\nCooling needs are determined by the production volume (bottles per hour), combined with the target filling temperature and the initial product temperature. High-speed bottling lines often require precise and stable chilling to maintain carbonation levels and product quality.<\/p>\n<p>Besides regular computation based on cooling Flow Rate and Temperature Drop,there is another way to size the chiller estimated based on pasteurizer capacity:<\/p>\n<p>Tunnel pasteurizer: typically 50\u2013150 kW per 10,000 bottles\/hour<\/p>\n<p>Flash pasteurizer: typically 30\u201380 kW per 10,000 L\/h<\/p>\n<p>Laser Equipment<br \/>\nFor laser applications, the cooling capacity is generally derived from the laser source power (kW) and the overall system efficiency. Fiber, CO\u2082, and solid-state lasers each have specific heat dissipation requirements, often with tight temperature stability tolerances.\u00a0There is a quick chiller sizing table by laser power:<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"236\">Laser Type<\/td>\n<td width=\"224\">Laser Power<\/td>\n<td width=\"500\">Recommended Chiller Capacity<\/td>\n<td width=\"500\">Notes<\/td>\n<\/tr>\n<tr>\n<td width=\"236\">Fiber Laser<\/td>\n<td width=\"224\">500W<\/td>\n<td width=\"500\">1.5-2.5KW<\/td>\n<td width=\"500\">Including optics<\/td>\n<\/tr>\n<tr>\n<td width=\"236\">Fiber Laser<\/td>\n<td width=\"224\">1KW<\/td>\n<td width=\"500\">3-4KW<\/td>\n<td width=\"500\">DI water required<\/td>\n<\/tr>\n<tr>\n<td width=\"236\">Fiber Laser<\/td>\n<td width=\"224\">2KW<\/td>\n<td width=\"500\">5-7KW<\/td>\n<td width=\"500\">Dual-circuit recommended<\/td>\n<\/tr>\n<tr>\n<td width=\"236\">Fiber Laser<\/td>\n<td width=\"224\">3-4KW<\/td>\n<td width=\"500\">8-12KW<\/td>\n<td width=\"500\">\u00b10.5\u2103 stability<\/td>\n<\/tr>\n<tr>\n<td width=\"236\">Fiber Laser<\/td>\n<td width=\"224\">6-8KW<\/td>\n<td width=\"500\">15-20KW<\/td>\n<td width=\"500\">For cutting\/welding<\/td>\n<\/tr>\n<tr>\n<td width=\"236\">CO\u2082 Laser (RF)<\/td>\n<td width=\"224\">500W<\/td>\n<td width=\"500\">3-4KW<\/td>\n<td width=\"500\">\u00b11\u2103 stability<\/td>\n<\/tr>\n<tr>\n<td width=\"236\">CO\u2082 Laser (RF)<\/td>\n<td width=\"224\">1KW<\/td>\n<td width=\"500\">6-8KW<\/td>\n<td width=\"500\">Includes optics cooling<\/td>\n<\/tr>\n<tr>\n<td width=\"236\">CO\u2082 Laser (RF)<\/td>\n<td width=\"224\">2KW<\/td>\n<td width=\"500\">12-15KW<\/td>\n<td width=\"500\">Dual-circuit often required<\/td>\n<\/tr>\n<tr>\n<td width=\"236\">CO\u2082 Laser (DC)<\/td>\n<td width=\"224\">1KW<\/td>\n<td width=\"500\">8-12KW<\/td>\n<td width=\"500\">Lower efficiency<\/td>\n<\/tr>\n<tr>\n<td width=\"236\">Ultrafast Laser<\/td>\n<td width=\"224\">50-200W<\/td>\n<td width=\"500\">2-5KW<\/td>\n<td width=\"500\">High precision required<\/td>\n<\/tr>\n<tr>\n<td width=\"236\">Diode Laser<\/td>\n<td width=\"224\">1KW<\/td>\n<td width=\"500\">1.5-2KW<\/td>\n<td width=\"500\">High efficiency<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Note: These are estimates. Actual requirements vary based on laser efficiency, duty cycle, ambient temperature, and specific system configuration.<\/p>\n<p>Hydraulic Systems<br \/>\nIn hydraulic presses and power units, the required chiller capacity is calculated based on the main motor power (kW). A common approach is to estimate that 20\u201330% of the hydraulic system&#8217;s input power is converted into heat, which must be removed to maintain stable oil temperature and system performance.<\/p>\n<p>For all the above cases, additional factors such as ambient temperature, circulation flow rate, and desired outlet temperature should also be considered to ensure accurate chiller sizing and reliable operation.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"FAQ\"><\/span>FAQ<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3><span class=\"ez-toc-section\" id=\"Why_Manual_Chiller_Capacity_Calculation_Still_Matters\"><\/span>Why Manual Chiller Capacity Calculation Still Matters?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Manually calculating can make engineers recognize on-site variables that the automatic tools might overlook, avoiding energy waste due to oversized selection or production shutdowns caused by insufficient capacity. So it increases the operational efficiency of the system.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"What_Happens_if_a_Chiller_is_Oversized\"><\/span>What Happens if a Chiller is Oversized?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>When the cooling capacity exceeds the actual demand, the chiller will quickly reach the set temperature and shut down. Subsequently, the water temperature will rise because of its low heat capacity, forcing the <a href=\"https:\/\/chillerone.com\/scroll-compressor\/\">scroll compressor<\/a>\u00a0or<a href=\"https:\/\/chillerone.com\/screw-compressor\/\">\u00a0screw compressor<\/a>\u00a0to restart frequently. This will shorten the lifespan of the compressor and lead to power waste.<\/p>\n<p>Moreover, oversized equipment also implies higher initial procurement costs and unnecessary space occupation.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"What_are_the_Key_Factors_That_Affect_Chiller_Capacity\"><\/span>What are the Key Factors That Affect Chiller Capacity?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-28121\" src=\"https:\/\/chillerone.com\/wp-content\/uploads\/2026\/03\/What-are-the-Key-Factors-That-Affect-Chiller-Capacity.jpg\" alt=\"What are the Key Factors That Affect Chiller Capacity\" width=\"1280\" height=\"720\" srcset=\"https:\/\/chillerone.com\/wp-content\/uploads\/2026\/03\/What-are-the-Key-Factors-That-Affect-Chiller-Capacity.jpg 1280w, https:\/\/chillerone.com\/wp-content\/uploads\/2026\/03\/What-are-the-Key-Factors-That-Affect-Chiller-Capacity-768x432.jpg 768w\" sizes=\"auto, (max-width: 1280px) 100vw, 1280px\" \/>The most crucial variable is the outlet water temperature (LWT). The flow fluctuations, altitude, and the accumulation of scale on the condenser all influence the actual output of your chiller. For air-cooled chillers, the ambient temperature is critical.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Can_I_Size_a_Chiller_without_Flow_Rate_Data\"><\/span>Can I Size a Chiller without Flow Rate Data?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>If there are no precise flow data, you can count roughly through empirical rules or process heat balance, but this will increase the risk of selection failure.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Manual_Calculation_vs_Supplier_Sizing_Whats_the_Difference\"><\/span>Manual Calculation vs Supplier Sizing, What\u2019s the Difference?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Manual calculation is mainly based on physical formulas, which enables you to independently verify the accuracy of the requirements, avoiding being sold oversized or incompatible machine models.<\/p>\n<p>Supplier sizing focuses on the effect of the chiller. They will refer to the curves of specific models of compressors and consider complex variables such as environmental temperature and altitude correction.<\/p>\n<p>To finally <a href=\"https:\/\/chillerone.com\/how-to-size-a-chiller\/\">determine the chiller size<\/a>, the most accurate way is to combine both methods.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"When_Should_You_Ask_for_Expert_Chiller_Sizing\"><\/span>When Should You Ask for Expert Chiller Sizing?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>When handling non-standard working process requirements, it is important for you to ask for a professional guide. For example, when your cooling requirements involve extremely low outlet water temperatures, when you use high-concentration glycol, when the chiller needs to be installed in high-altitude or extremely hot regions, or when you need multiple chillers to operate in parallel.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Final_Thoughts\"><\/span>Final Thoughts<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Accurate chiller cooling capacity calculation is vital for building an efficient cooling system. Although manual calculation lets you become more familiar with process requirements, an expert sizing from a professional supplier is also necessary. <a href=\"https:\/\/chillerone.com\/\">Chillerone<\/a>\u00a0chiller solutions are always designed based on precise heat load analysis, especially according to your working process. We welcome you to <a href=\"https:\/\/chillerone.com\/contact-us\/\">contact us<\/a>\u00a0to obtain a customized cooler selection plan tailored to your process.<\/p>\n<p><a href=\"#contactPopUpForm\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-28124 size-full\" src=\"https:\/\/chillerone.com\/wp-content\/uploads\/2026\/03\/Stable-Refrigeration-Unitsfor-Continuous-Cooling.jpg\" alt=\"Stable Refrigeration Units for Continuous Cooling\" width=\"1280\" height=\"720\" srcset=\"https:\/\/chillerone.com\/wp-content\/uploads\/2026\/03\/Stable-Refrigeration-Unitsfor-Continuous-Cooling.jpg 1280w, https:\/\/chillerone.com\/wp-content\/uploads\/2026\/03\/Stable-Refrigeration-Unitsfor-Continuous-Cooling-768x432.jpg 768w\" sizes=\"auto, (max-width: 1280px) 100vw, 1280px\" \/><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>For chiller procurement managers and cooling process engineers, choosing a properly sized chiller is vital to avoid costly oversizing or insufficient cooling. This makes it essential to know how to manually calculate chiller capacity for your process. In this article, we show you the calculation method step by step. Chiller [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":28119,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-28112","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>How to Calculate Chiller Capacity for Your Process Manually\u2014A Step-by-Step Guide - ChillerOne<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/\" \/>\n<meta property=\"og:locale\" content=\"ar_AR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to Calculate Chiller Capacity for Your Process Manually\u2014A Step-by-Step Guide - ChillerOne\" \/>\n<meta property=\"og:description\" content=\"For chiller procurement managers and cooling process engineers, choosing a properly sized chiller is vital to avoid costly oversizing or insufficient cooling. This makes it essential to know how to manually calculate chiller capacity for your process. In this article, we show you the calculation method step by step. Chiller [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/\" \/>\n<meta property=\"og:site_name\" content=\"ChillerOne\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-31T05:37:40+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-28T01:09:51+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/chillerone.com\/wp-content\/uploads\/2026\/03\/Manually-Calculate-Chiller-Capacity-Steps.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1280\" \/>\n\t<meta property=\"og:image:height\" content=\"720\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Chillerone\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0643\u064f\u062a\u0628 \u0628\u0648\u0627\u0633\u0637\u0629\" \/>\n\t<meta name=\"twitter:data1\" content=\"Chillerone\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u0648\u0642\u062a \u0627\u0644\u0642\u0631\u0627\u0621\u0629 \u0627\u0644\u0645\u064f\u0642\u062f\u0651\u0631\" \/>\n\t<meta name=\"twitter:data2\" content=\"12 \u062f\u0642\u064a\u0642\u0629\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/chillerone.com\\\/how-to-calculate-chiller-capacity-for-your-process-manually\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/chillerone.com\\\/how-to-calculate-chiller-capacity-for-your-process-manually\\\/\"},\"author\":{\"name\":\"Chillerone\",\"@id\":\"https:\\\/\\\/chillerone.com\\\/#\\\/schema\\\/person\\\/f7aa09a0e4260f4d6da78359d738782b\"},\"headline\":\"How to Calculate Chiller Capacity for Your Process Manually\u2014A Step-by-Step Guide\",\"datePublished\":\"2026-03-31T05:37:40+00:00\",\"dateModified\":\"2026-07-28T01:09:51+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/chillerone.com\\\/how-to-calculate-chiller-capacity-for-your-process-manually\\\/\"},\"wordCount\":2238,\"publisher\":{\"@id\":\"https:\\\/\\\/chillerone.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/chillerone.com\\\/how-to-calculate-chiller-capacity-for-your-process-manually\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/chillerone.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/Manually-Calculate-Chiller-Capacity-Steps.jpg\",\"articleSection\":[\"Blog\"],\"inLanguage\":\"ar\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/chillerone.com\\\/how-to-calculate-chiller-capacity-for-your-process-manually\\\/\",\"url\":\"https:\\\/\\\/chillerone.com\\\/how-to-calculate-chiller-capacity-for-your-process-manually\\\/\",\"name\":\"How to Calculate Chiller Capacity for Your Process Manually\u2014A Step-by-Step Guide - ChillerOne\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/chillerone.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/chillerone.com\\\/how-to-calculate-chiller-capacity-for-your-process-manually\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/chillerone.com\\\/how-to-calculate-chiller-capacity-for-your-process-manually\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/chillerone.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/Manually-Calculate-Chiller-Capacity-Steps.jpg\",\"datePublished\":\"2026-03-31T05:37:40+00:00\",\"dateModified\":\"2026-07-28T01:09:51+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/chillerone.com\\\/how-to-calculate-chiller-capacity-for-your-process-manually\\\/#breadcrumb\"},\"inLanguage\":\"ar\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/chillerone.com\\\/how-to-calculate-chiller-capacity-for-your-process-manually\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ar\",\"@id\":\"https:\\\/\\\/chillerone.com\\\/how-to-calculate-chiller-capacity-for-your-process-manually\\\/#primaryimage\",\"url\":\"https:\\\/\\\/chillerone.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/Manually-Calculate-Chiller-Capacity-Steps.jpg\",\"contentUrl\":\"https:\\\/\\\/chillerone.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/Manually-Calculate-Chiller-Capacity-Steps.jpg\",\"width\":1280,\"height\":720,\"caption\":\"Manually Calculate Chiller Capacity Steps\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/chillerone.com\\\/how-to-calculate-chiller-capacity-for-your-process-manually\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/chillerone.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Calculate Chiller Capacity for Your Process Manually\u2014A Step-by-Step Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/chillerone.com\\\/#website\",\"url\":\"https:\\\/\\\/chillerone.com\\\/\",\"name\":\"ChillerOne\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/chillerone.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/chillerone.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ar\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/chillerone.com\\\/#organization\",\"name\":\"ChillerOne\",\"url\":\"https:\\\/\\\/chillerone.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ar\",\"@id\":\"https:\\\/\\\/chillerone.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/chillerone.com\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/chillerone.com\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/logo.png\",\"width\":251,\"height\":64,\"caption\":\"ChillerOne\"},\"image\":{\"@id\":\"https:\\\/\\\/chillerone.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/chillerone.com\\\/#\\\/schema\\\/person\\\/f7aa09a0e4260f4d6da78359d738782b\",\"name\":\"Chillerone\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ar\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/0a8a1d7ef86fb59a68e9545065f759eb22730a8e426b36a93e326ff57a274385?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/0a8a1d7ef86fb59a68e9545065f759eb22730a8e426b36a93e326ff57a274385?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/0a8a1d7ef86fb59a68e9545065f759eb22730a8e426b36a93e326ff57a274385?s=96&d=mm&r=g\",\"caption\":\"Chillerone\"},\"url\":\"https:\\\/\\\/chillerone.com\\\/ar\\\/author\\\/dp_admin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u0643\u064a\u0641\u064a\u0629 \u062d\u0633\u0627\u0628 \u0633\u0639\u0629 \u0627\u0644\u0645\u0628\u0631\u062f \u0644\u0639\u0645\u0644\u064a\u062a\u0643 \u064a\u062f\u0648\u064a\u064b\u0627 - \u062f\u0644\u064a\u0644 \u062e\u0637\u0648\u0629 \u0628\u062e\u0637\u0648\u0629 - ChillerOne","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/","og_locale":"ar_AR","og_type":"article","og_title":"How to Calculate Chiller Capacity for Your Process Manually\u2014A Step-by-Step Guide - ChillerOne","og_description":"For chiller procurement managers and cooling process engineers, choosing a properly sized chiller is vital to avoid costly oversizing or insufficient cooling. This makes it essential to know how to manually calculate chiller capacity for your process. In this article, we show you the calculation method step by step. Chiller [&hellip;]","og_url":"https:\/\/chillerone.com\/ar\/how-to-calculate-chiller-capacity-for-your-process-manually\/","og_site_name":"ChillerOne","article_published_time":"2026-03-31T05:37:40+00:00","article_modified_time":"2026-07-28T01:09:51+00:00","og_image":[{"width":1280,"height":720,"url":"https:\/\/chillerone.com\/wp-content\/uploads\/2026\/03\/Manually-Calculate-Chiller-Capacity-Steps.jpg","type":"image\/jpeg"}],"author":"Chillerone","twitter_card":"summary_large_image","twitter_misc":{"\u0643\u064f\u062a\u0628 \u0628\u0648\u0627\u0633\u0637\u0629":"Chillerone","\u0648\u0642\u062a \u0627\u0644\u0642\u0631\u0627\u0621\u0629 \u0627\u0644\u0645\u064f\u0642\u062f\u0651\u0631":"12 \u062f\u0642\u064a\u0642\u0629"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/chillerone.com\/how-to-calculate-chiller-capacity-for-your-process-manually\/#article","isPartOf":{"@id":"https:\/\/chillerone.com\/how-to-calculate-chiller-capacity-for-your-process-manually\/"},"author":{"name":"Chillerone","@id":"https:\/\/chillerone.com\/#\/schema\/person\/f7aa09a0e4260f4d6da78359d738782b"},"headline":"How to Calculate Chiller Capacity for Your Process Manually\u2014A Step-by-Step Guide","datePublished":"2026-03-31T05:37:40+00:00","dateModified":"2026-07-28T01:09:51+00:00","mainEntityOfPage":{"@id":"https:\/\/chillerone.com\/how-to-calculate-chiller-capacity-for-your-process-manually\/"},"wordCount":2238,"publisher":{"@id":"https:\/\/chillerone.com\/#organization"},"image":{"@id":"https:\/\/chillerone.com\/how-to-calculate-chiller-capacity-for-your-process-manually\/#primaryimage"},"thumbnailUrl":"https:\/\/chillerone.com\/wp-content\/uploads\/2026\/03\/Manually-Calculate-Chiller-Capacity-Steps.jpg","articleSection":["Blog"],"inLanguage":"ar"},{"@type":"WebPage","@id":"https:\/\/chillerone.com\/how-to-calculate-chiller-capacity-for-your-process-manually\/","url":"https:\/\/chillerone.com\/how-to-calculate-chiller-capacity-for-your-process-manually\/","name":"\u0643\u064a\u0641\u064a\u0629 \u062d\u0633\u0627\u0628 \u0633\u0639\u0629 \u0627\u0644\u0645\u0628\u0631\u062f \u0644\u0639\u0645\u0644\u064a\u062a\u0643 \u064a\u062f\u0648\u064a\u064b\u0627 - \u062f\u0644\u064a\u0644 \u062e\u0637\u0648\u0629 \u0628\u062e\u0637\u0648\u0629 - ChillerOne","isPartOf":{"@id":"https:\/\/chillerone.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/chillerone.com\/how-to-calculate-chiller-capacity-for-your-process-manually\/#primaryimage"},"image":{"@id":"https:\/\/chillerone.com\/how-to-calculate-chiller-capacity-for-your-process-manually\/#primaryimage"},"thumbnailUrl":"https:\/\/chillerone.com\/wp-content\/uploads\/2026\/03\/Manually-Calculate-Chiller-Capacity-Steps.jpg","datePublished":"2026-03-31T05:37:40+00:00","dateModified":"2026-07-28T01:09:51+00:00","breadcrumb":{"@id":"https:\/\/chillerone.com\/how-to-calculate-chiller-capacity-for-your-process-manually\/#breadcrumb"},"inLanguage":"ar","potentialAction":[{"@type":"ReadAction","target":["https:\/\/chillerone.com\/how-to-calculate-chiller-capacity-for-your-process-manually\/"]}]},{"@type":"ImageObject","inLanguage":"ar","@id":"https:\/\/chillerone.com\/how-to-calculate-chiller-capacity-for-your-process-manually\/#primaryimage","url":"https:\/\/chillerone.com\/wp-content\/uploads\/2026\/03\/Manually-Calculate-Chiller-Capacity-Steps.jpg","contentUrl":"https:\/\/chillerone.com\/wp-content\/uploads\/2026\/03\/Manually-Calculate-Chiller-Capacity-Steps.jpg","width":1280,"height":720,"caption":"Manually Calculate Chiller Capacity Steps"},{"@type":"BreadcrumbList","@id":"https:\/\/chillerone.com\/how-to-calculate-chiller-capacity-for-your-process-manually\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/chillerone.com\/"},{"@type":"ListItem","position":2,"name":"How to Calculate Chiller Capacity for Your Process Manually\u2014A Step-by-Step Guide"}]},{"@type":"WebSite","@id":"https:\/\/chillerone.com\/#website","url":"https:\/\/chillerone.com\/","name":"\u062a\u0634\u064a\u0644\u0631 \u0648\u0627\u0646","description":"","publisher":{"@id":"https:\/\/chillerone.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/chillerone.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ar"},{"@type":"Organization","@id":"https:\/\/chillerone.com\/#organization","name":"\u062a\u0634\u064a\u0644\u0631 \u0648\u0627\u0646","url":"https:\/\/chillerone.com\/","logo":{"@type":"ImageObject","inLanguage":"ar","@id":"https:\/\/chillerone.com\/#\/schema\/logo\/image\/","url":"https:\/\/chillerone.com\/wp-content\/uploads\/2025\/12\/logo.png","contentUrl":"https:\/\/chillerone.com\/wp-content\/uploads\/2025\/12\/logo.png","width":251,"height":64,"caption":"ChillerOne"},"image":{"@id":"https:\/\/chillerone.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/chillerone.com\/#\/schema\/person\/f7aa09a0e4260f4d6da78359d738782b","name":"\u062a\u0634\u064a\u0644\u064a\u0631\u0648\u0646\u064a","image":{"@type":"ImageObject","inLanguage":"ar","@id":"https:\/\/secure.gravatar.com\/avatar\/0a8a1d7ef86fb59a68e9545065f759eb22730a8e426b36a93e326ff57a274385?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/0a8a1d7ef86fb59a68e9545065f759eb22730a8e426b36a93e326ff57a274385?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/0a8a1d7ef86fb59a68e9545065f759eb22730a8e426b36a93e326ff57a274385?s=96&d=mm&r=g","caption":"Chillerone"},"url":"https:\/\/chillerone.com\/ar\/author\/dp_admin\/"}]}},"_links":{"self":[{"href":"https:\/\/chillerone.com\/ar\/wp-json\/wp\/v2\/posts\/28112","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chillerone.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/chillerone.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/chillerone.com\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/chillerone.com\/ar\/wp-json\/wp\/v2\/comments?post=28112"}],"version-history":[{"count":16,"href":"https:\/\/chillerone.com\/ar\/wp-json\/wp\/v2\/posts\/28112\/revisions"}],"predecessor-version":[{"id":29609,"href":"https:\/\/chillerone.com\/ar\/wp-json\/wp\/v2\/posts\/28112\/revisions\/29609"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chillerone.com\/ar\/wp-json\/wp\/v2\/media\/28119"}],"wp:attachment":[{"href":"https:\/\/chillerone.com\/ar\/wp-json\/wp\/v2\/media?parent=28112"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/chillerone.com\/ar\/wp-json\/wp\/v2\/categories?post=28112"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/chillerone.com\/ar\/wp-json\/wp\/v2\/tags?post=28112"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}