Chiller Solution to Match DWC Brand
Why Choose Chillerone DWC Chillers?
- Optimized for continuous circulation of nutrient-rich water, preventing oxygen depletion and root disease.
- Nonstop operation under high humidity and high load conditions.
- Custom sizes to adapt from small rooms to large-scale commercial farms.
- High-efficiency compressors and heat exchange reduce power consumption and your operating costs.
- Enable handling sudden heat loads without temperature fluctuation.
Chillerone—Your Reliable DWC Chiller Supplier
With over 20 years of experience committed to designing and manufacturing DWC chillers, our company exports more than 80% of its products. Up to now, Chillerone has won the reliance of customers in over 75 countries and regions. We have established a stable sales channel and offer reliable after-sales service, ensuring that every customer can receive professional services and high-quality products.
Choose Your Suitable Type of DWC Chillers
Whether a small indoor grow or a large commercial hydroponic farm, we offer various sizes and configurations of water chillers and are able to customize ones according to your specific needs.

Discharge heat by cooling the water with the fan. Quick deployment and simple maintenance, suitable for compact DWC systems (such as small grow rooms or greenhouses).

Remove heat through the circulating cooling water. Have higher efficiency, suitable for commercial DWC systems with high capacity and long operation time.

Equipped with PID control, LCD, APP or remote monitoring, ensuring precise temperature control, and improving plant yield and consistency.

Equipped with a built-in circulating pump, which directly drives the water flow. Simple installation, saving the additional cost of the circulation system.

The refrigeration unit and the cooling tank are separated, allowing for flexible installation based on space requirements.

supports multiple independent water tanks with one main unit, and provides individual temperature control. Suitable for growing multiple crops or different growth stages.

Has automatic defrosting functions and can prevent water pipes from freezing in low-temperature conditions.

Usually has a small capacity of 50–200L. Compact, energy-efficient, easy to transport, suitable for individual grow rooms.

Installed on the wall or on an overhead bracket. Saves floor space, safe and tidy, suitable for small indoor farms with limited space.

Has a large capacity, strong stability, easy maintenance and expansion, suitable for commercial grow rooms.

Has high energy efficiency and stable temperature control. Ensures the health of the root zone of leafy greens and increases yield.

Allow for low noise and 24/7 continuous operation. Reduces growth stress and enhances cannabinoid consistency.
Benefits that You Can Receive from Our DWC Chillers
Chillerone DWC chillers come with a variety of advanced features and flexible options to meet the various unique requirements of commercial hydroponic projects. Explore the key features that make them ideal for your DWC operations.

Consistent nutrient solution temperature within ±0.5°C

Nonstop operation to ensure uninterrupted cooling performance.

Available in multiple cooling capacities to support small to large-scale uses.

High-efficiency components reduce energy consumption.

All components are corrosion-resistant and designed for long-term use.

User-friendly design allows for installation, setup, and maintenance.

Support private labeling or custom specifications for commercial DWC projects.

Supports multiple DWC tanks’ temperature control for different crop types.

The quiet operation mode can minimize the disruption to the plant’s growth.

Equipped with alerts to avoid over-temperature faults and other equipment failures.

The extensible modules enable the system to be freely expanded to a larger DWC system without replacing the entire device.

Supports different international power standards.
Accurate and Constant Temperature Management
Typical industrial or modified chillers will fluctuate by a few degrees when facing changing loads, whereas Chillerone DWC chillers are equipped with high-precision temperature sensors, advanced PID controllers, and variable-speed compressors, designed to maintain the temperature of the nutrient solution within ±0.5°C during 24/7 operation. Our DWC chillers continuously monitor the temperature and adjust the output power of the compressor in time to keep a stable water temperature. When facing sudden high-temperature peaks or multiple reservoir settings, the system can prevent deviations to fit differences in water volume, ambient temperature, and heat generated by lighting, maximizing dissolved oxygen levels and guaranteeing the stability of the root zone environment, thus providing the best environments for the growth of your plants.


Rapid Response to Heat Spikes
Equipped with high-performance compressors and optimized heat exchangers, the Chillerone DWC water chiller is able to absorb sudden increases in heat in time, prevent root compression, and ensure that the system can run constantly during the plant growth period, even in peak electricity usage times or when there are unanticipated heat loads. This enables real-time maintenance of stable nutrient solution temperatures in large-scale or multi-reservoir systems and protects root health. Thus, it protects your crops from sudden temperature changes.
Advanced Intelligent Monitoring with Automatic Adjustment
Unlike standard chillers, our DWC water chiller is equipped with multi-point temperature sensing, real-time data logging, optional remote access, and automated compressor modulation, allowing you to monitor temperature, set alarms, and adjust them wherever you are. This prevents overheating or temperature instability, ensuring stable conditions for continuous root health. Thus, Chillerone DWC chillers can help you enable stable output and uniform plant quality.

Reliable Certification
Complying with global agricultural safety codes, this certified chiller ensures pollution-free operation for edible crop hydroponics.
DWC Chiller Applications

DWC chillers can be used in large-scale vertical cannabis cultivation. They keep the root zone thermally balanced even under powerful grow lights, protecting steady cannabis development over time and preventing the occurrence of root diseases.

Chillerone DWC chillers are designed specifically for the DWC system that can be used for growing lettuce, basil, and other leafy vegetables. The precise nutrient solution temperature is essential to maintaining root system health and shortened growth timelines.

We offer DWC chillers designed specifically for indoor grow environments where air circulation is restricted and the heat load is high. They provide stable and dependable thermal control for the nutrient reservoir throughout the entire growth cycle.

DWC chillers are ideal for application in greenhouses because exposure to sunlight and surrounding conditions can lead to unstable water temperatures, thus ensuring the stable cooling of the root area.

DWC technology can be combined with the nursery pond. In this case, the DWC chiller is engineered to keep the water at stable temperatures of the biological floc system, providing the most secure starting point for the growth of seedlings, significantly improving the survival rate and uniformity of the seedlings.
Strict Quality Control
All raw materials entering the production line are strictly inspected to ensure they meet industrial standards, and we use advanced testing equipment to monitor whether each step meets the predetermined quality standards.
After each operation is completed, multiple functional tests and inspections are conducted on components and finished products, such as pressure tests and temperature cycling tests, to ensure the safety and reliability of the products.
- Compare Chillerone DWC Chillers with General Industry Chillers
DWC environments demand stricter temperature control and greater reliability than standard industrial processes. This comparison chart explains why Chillerone dedicated DWC water chillers can achieve more stable results.
| General Industry Chillers | Our DWC Chillers |
| Designed for general machines | Designed for nutrient solution |
| No DWC load calculation | Matched to DWC constant circulation |
| Low resistance to humid conditions | Anti-corrosion & sealed design |
| Unstable temperature control | ±0.5°C stable control or even more precise |
See the DWC Chiller in Action
Watch how the DWC chiller delivers stable temperature control, fast cooling response, and reliable performance in real industrial working conditions.
What is a DWC Chiller?
A DWC (Deep Water Culture) chiller is a specially designed water cooling system used to regulate the temperature of the nutrient solution in a Deep Water Culture (DWC) hydroponic system. During DWC growth, even a slight temperature fluctuation can reduce the oxygen level, resulting in a negative impact on plant growth.
Unlike general industrial chillers, the DWC chiller must be designed to operate continuously under high humidity conditions and handle nutrient-rich water of your DWC root zone. To achieve this, our DWC chillers are specifically designed for hydroponic applications, providing precise temperature control and reliable 24/7 cooling to support high-yield DWC operations in grow rooms and greenhouses. By maintaining the water in the root zone within the optimal temperature range, Chillerone DWC chillers help to maintain the dissolved oxygen level, promote healthy root development, and prevent various problems such as oxygen depletion and root rot, giving long-term reliability for commercial DWC growing projects.
How Does a DWC Chiller Support Your Hydroponic Systems?
The DWC chiller operates based on the principle of the vapor compression refrigeration cycle.
First, the warm nutrient solution from the hydroponic system is pumped out through the evaporator, and the liquid refrigerant absorbs heat from the water, turning it into a low-pressure, low-temperature gas. The compressor will increase the pressure and temperature of this gas significantly. Then, high-temperature and high-pressure gas flows into the condenser, which acts as another heat exchanger. During this process, the refrigerant releases the accumulated heat into the surrounding environment.
As the heat dissipates, the refrigerant recondenses into a high-pressure liquid state. The high-pressure liquid refrigerant flows through the expansion valve, which causes its pressure and temperature to drop rapidly, which prepares the refrigerant to enter the evaporator again, thus beginning the next cycle.
In this way, the DWC chiller transfers the heat energy from the warm nutrient solution to the cooler external environment, maintaining a constant and ideal temperature in the DWC system.
What’s more, the built-in digital controller monitors the water temperature and automatically controls the opening and closing of the compressor to maintain the set temperature point, ensuring the stable temperature required for your plant growth.
Why Do You Need a DWC Chiller?
To Prevent Root Diseases
An increase in water temperature reduces the dissolved oxygen content and increases the risk of diseases such as root rot. The DWC chiller can control the water temperature within a safe range to protect the health of the roots.
Maintain a Stable Dissolved Oxygen Level
Water temperature directly affects the content of dissolved oxygen and influences the supply of oxygen. A DWC chiller helps maintain a stable oxygen level, promoting healthier and more adaptable root growth.
Avoid Temperature Fluctuations in High-Load Systems
Multiple water tanks, high-power lighting equipment, and continuous operation can lead to rapid temperature changes, and a DWC chiller can stabilize the water temperature and ensure stable system performance even under peak load conditions.
Reduce Human Intervention and System Risks
Without a chiller, growers often need to make manual adjustments due to the lack of precise temperature control. With an automatic DWC chiller, your need for human effort and operational risks is reduced.
Why Can You Trust Chillerone?
High Productivity
We have over 300 chiller models and 3000 world-class equipments. We produce 9000 chiller units and 200,000 various chillers every year. Our annual sales have reached US$35milliom.
Strong Capabilities
Chillerone has an area of 660,000 square meters for the factory and a total area of 1,000,000 square meters for the industrial. We have 5 international advanced online monitoring systems and 2 national laboratories.
Export-Oriented
We have served local professional growers, system integrators, and distributors in more than 75 countries and regions around the world, and more than 80% of our products are exported.
Reliable After-Sales Support
We offer a 7*24*365 customer service hotline and online support to meet the needs of customers from different time zones and quickly resolve customers’ after-sales service issues, achieving a response within 2 hours, arrival at the scene within 6 hours.
Return Visit Customers
We archive the installed customer systems and conduct regular phone and email follow-ups. We will also visit the customers in person and provide guidance and re-training for their usage if conditions permit.
Extended Warranty
We provide a 12-month free warranty period for each machine, and it can be extended to 5 years. Within the warranty period, we provide all kinds of after-sales services free of charge until the problem is resolved.
In most cases, using the DWC chiller is the most effective cooling method to maintain the ideal temperature range of 65°F to 72°F (18°C to 22°C) for your root zone, which maximizes dissolved oxygen (DO) levels and prevents the growth of harmful pathogens such as root rot. That means, it’s highly recommended to install chillers, especially for grow rooms whose temperature is above 65-68°F.
The size (cooling capacity) of the DWC chiller is decided by the total water consumption, ambient temperature, heat generated by lighting and pumps, and the target water temperature. Strictly, it needs a professional heat load calculation. The basic formula is: Required cooling capacity (kW) = Water volume (liters) × Temperature difference × Coefficient / Time. The easiest way is to contact us, and our experienced team will calculate it for you.
We do not recommend that because not all industrial chillers are suitable for DWC applications. DWC chillers require materials compatible with the nutrient solution, stable low-temperature control, and corrosion-resistant components. Chillers specifically designed for DWC are engineered to operate reliably in agricultural environments and can support long-term water quality assurance.
The installation position of the DWC chiller should be well-ventilated. It’s recommended to choose the area outside the main planting tent or room. Air-cooled chillers will disperse heat, so placing the equipment outside the warm planting space can prevent the surrounding environment temperature from rising. Our sales consultant will recommend the best model and installation location based on your site layout.
Usually, a chiller needs a submersible or external pump, with a flow rate sufficient to allow water to circulate within the cooler and return to the system. The user manual we provide will indicate the recommended GPH range for you.
To install the pipes, we will connect one hose from the pump’s outlet to the cooler’s inlet, and then connect another hose from the cooler’s outlet back to the water storage container or the planting tank. Finally, we will inspect if all the connections are fixed with hose clamps to prevent leakage.
We recommend you check and clean the filter monthly, ensure the chemical properties of the water are appropriate to prevent scaling in the system, and conduct a leak test annually.
Yes. If the total water volume and heat load of the chiller are both within the cooling capacity range of the unit, then one chiller can simultaneously provide cooling services for multiple water tanks. Reasonable pipeline design and flow control are crucial for ensuring that all water tanks receive uniform cooling.
If the DWC chiller does not work well, you can check if the set temperature is right, and inspect the vents and filters to see if they need cleaning. The adequacy of the water flow would also lead to the pump and hose being bent or clogged. Besides, ensure there is sufficient space (12-24 inches) around the equipment to dissipate heat. Of course, you can contact us directly, and our engineers will provide professional advice to you.
The chiller will generate noise when the compressor is running. You can place the DWC chiller outside of the growing area or use a remote installation method to alleviate this issue. Chillerone can also provide some models with lower noise.
Our DWC chillers are made with stainless steel water tanks, stainless steel pumps, and food-grade materials for all components that come into contact with water, which can help prevent corrosion, contamination, and performance degradation over time.