Marcas internacionales con las que colaboramos
Why Choose our Industrial Air Chillers
- Compresor scroll for higher energy efficiency
- Intelligent PLC system to accurately control temperature
- Automatic load detection
- Copper coils to maximize heat transfer
- Large cooling capacity up to 250 tons.
Your Leading Industrial Air Cooled Chiller Manufacturer since 1999
If you are operating a small to medium-sized industrial process, ChillerOne’s industrial air-cooled chiller will save you the extra expenses that come with cooling tower installation and water treatment.
A diferencia de enfriadores de agua industriales that reject heat through a torre de refrigeración, our air-cooled chillers transfer unwanted heat directly to the ambient air. Therefore, you can install these chillers where water is scarce since they don’t use water in a cooling tower to reject heat.
The PID control in our chillers automatically detects load and adjusts compressor performance. This ensures our compressors have stepless operations to eliminate temperature fluctuation and guarantee quiet operation.
For more efficient heat transfer, we use copper tubing, which effectively absorbs heat and increases both transfer and rejection into ambient air.
At ChillerOne, we size industrial air-cooled chillers according to your cooling requirements. Partner with us today and let our engineers offer a practical solution to your dynamic cooling needs. With every air-cooled chiller, we offer a 100% quality guarantee.

A great environmental chiller for large areas, such as rinks. Alternative cooling machine for heavy duty.

Easy to operate and industrial air cooler for various applications and efficient low temperature control with remote manual control type.

Adjustable control over temperature and smooth function, Ideal for swimming pool or other wide industrial use.

Great compressor and air chiller, Energy efficient and great heat dissipation. Has both manual and digital control type.

A storage cooled chiller and High efficiency heat exchange. Constant temperature control and saving-energy consumption.

Fast cooling of low temperature, has constant temperature control that has dual manual and digital control type.

Eco-friendly and easy to operate, Has semi-hermitic reciprocator for constant temperature use along with heat dissipation.

A wide application for material shops with need of constant cold temperatures. Customizable for various optimizations.
Certificación confiable
Ensure uninterrupted production with our ISO-standard industrial air cooled chiller models. Equipped with high-efficiency fins and robust fans, these units are engineered to deliver consistent cooling performance even in high-ambient temperature environments and dusty industrial settings.
Applications of Industrial Air Cooled Chillers

Our industrial air cooled chillers can provide precise temperature control for molds and hydraulic oil in equipment such as injection molding machines and extruders. By quickly removing the large amount of heat generated during the plastic molding process, it can significantly shorten the cooling cycle of your products, improve production efficiency, and at the same time ensure the dimensional stability of your products.

In the field of laser processing, ChillerOne industrial air cooled chillers can provide stable cooling for the laser generators and processing heads of laser cutting machines and laser welding machines, which effectively prevents your equipment from experiencing fluctuations in output power and a decline in beam quality due to overheating. While ensuring processing accuracy, they can also extend the service life of the laser.

Industrial air cooled chillers are widely used in CNC machine tools, machining centers, grinders and other equipment. Its main function is to cool the motor and bearings of the main shaft, the hydraulic oil of the hydraulic system, etc. It can effectively suppress the thermal deformation of machine tools, ensuring the realization of your high-precision processing, while extending the tool life and maintaining the performance of the cutting fluid.

In the chemical and pharmaceutical processes, our industrial air cooled chillers are used to provide process cooling for reactors, condensers, biological fermentation tanks, etc. It ensures that chemical reactions proceed efficiently along the predetermined path through precise temperature control, which guarantees the quality of your products and production safety. In addition, its closed-loop system effectively avoids the risk of contamination of your production process by the cooling medium.
- Especificación
- Video
- Piezas de repuesto
- Ejemplos de aplicaciones exitosas
Industrial Air Cooled Chiller Technical Specifications
| Elementos\Modelo | CA-0,5 A | AC-1A | CA-1.5A | AC-2A | CA-2.5A | AC-3A | AC-4A | AC-5A | AC-6A | AC-8AD | AC-10AD | AC-12AD | AC-15AD | |
| Capacidad de refrigeración | kcal/h 50 Hz/60 Hz | 1419 | 2451 | 3182 | 4833 | 5848 | 7181 | 9288 | 11988 | 14534 | 18576 | 23994 | 29068 | 38270 |
| 1703 | 2941 | 3784 | 5800 | 7018 | 8617 | 11146 | 14386 | 17441 | 22291 | 28793 | 34882 | 45924 | ||
| KW 50 Hz/60 Hz | 1.65 | 2.85 | 3.7 | 5.62 | 6.8 | 8.35 | 10.8 | 13.94 | 16.9 | 21.6 | 27.9 | 33.8 | 44.5 | |
| 1.98 | 3.42 | 4.4 | 6.74 | 8.2 | 10.02 | 12.96 | 16.73 | 20.28 | 25.92 | 33.48 | 40.56 | 53.4 | ||
| Potencia de entrada | KW | 0.88 | 1.35 | 2 | 2.25 | 2.66 | 3.27 | 4.07 | 5.75 | 6.45 | 8.25 | 11.5 | 12.9 | 17.45 |
| Corriente máxima | A | 5.4 | 8.2 | 12 | 13.6 | 6.6 | 8.2 | 10.1 | 13.8 | 15.5 | 20 | 27.9 | 31.3 | 42.4 |
| Fuente de alimentación | 1PH~220V/3PH~220V/380V 50HZ/60HZ | 3PH~380V/415V/480V~50HZ/60HZ(3PH~200V/220V 50HZ/60HZ) | ||||||||||||
| Refrigerante | Tipo | R22/R407C/134a/404A/410A | ||||||||||||
| Control | Válvula de expansión capilar/termostática | |||||||||||||
| Compresor | Tipo | Rotor hermético | Enrollador hermético (pistón) | |||||||||||
| Potencia (kW) | 0.45 | 0.89 | 1.3 | 1.73 | 2.1 | 2.7 | 3.5 | 4.55 | 5.25 | 3.5×2 | 4.55×2 | 5.25×2 | 7×2 | |
| Condensador | Tipo | Tubo de cobre con aletas de alta eficiencia y ventilador de rotor externo de aluminio y bajo nivel de ruido. | ||||||||||||
| Caudal de aire (m³/h) | 750 | 1000 | 1500 | 2000 | 2500 | 3000 | 4000 | 5000 | 6000 | 8000 | 10000 | 12000 | 15000 | |
| Soplador de aire (KW) | 0.06 | 0.09 | 0.15 | 0.15 | 0.19 | 0.14×2 | 0.14×2 | 0.19×2 | 0.19×2 | 0.25×2 | 0.45×2 | 0.45×2 | 0.6×2 | |
| Evaporador | Tipo | Serpentín de tanque de acero inoxidable / tipo carcasa y tubo / intercambiador de calor de placas | ||||||||||||
| Agua fría (m³/h) | 0.28 | 0.49 | 0.64 | 0.97 | 1.12 | 1.44 | 1.86 | 2.4 | 2.91 | 3.71 | 4.8 | 5.81 | 7.65 | |
| 0.34 | 0.59 | 0.76 | 1.16 | 1.4 | 1.72 | 2.23 | 2.88 | 3.49 | 4.46 | 5.76 | 7 | 9.18 | ||
| depósito de agua (L) | 10.6 | 18.3 | 27 | 27 | 50 | 50 | 60 | 60 | 110 | 120 | 200 | 200 | 270 | |
| Tubo de entrada/salida (pulgada) i | 1/2″ | 1/2″ | 1/2″ | 1/2″ | 1″ | 1″ | 1″ | 1″ | 1″ | 1-1/2″ | 2″ | 2″ | 2″ | |
| Bomba de agua | Potencia (kW) | 0.37 | 0.37 | 0.37 | 0.37 | 0.37 | 0.37 | 0.37 | 0.75 | 0.75 | 0.75 | 1.5 | 1.5 | 2.2 |
| Elevación máxima (m) | 22 | 22 | 22 | 22 | 22 | 22 | 22 | 30 | 30 | 25 | 25 | 25 | 28 | |
| Caudal máximo (m3) | 5.4 | 5.4 | 5.4 | 5.4 | 5.4 | 5.4 | 5.4 | 8.1 | 8.1 | 8.1 | 13.5 | 13.5 | 25.2 | |
| Protección de seguridad | Protección interna del compresor, protección contra sobrecorriente, protección contra alta/baja presión, protección contra sobretemperatura, protección de caudal, protección contra secuencia de fases/falta de fase, protección contra bajo nivel de refrigerante, protección anticongelante, protección contra sobrecalentamiento del escape. | |||||||||||||
| Dimensión | L(mm) | 550 | 550 | 600 | 600 | 720 | 980 | 980 | 1150 | 1150 | 1350 | 1500 | 1500 | 1860 |
| Ancho (mm) | 350 | 450 | 500 | 500 | 550 | 520 | 520 | 560 | 560 | 680 | 760 | 760 | 850 | |
| Mmm) | 695 | 845 | 985 | 985 | 1350 | 1170 | 1170 | 1215 | 1215 | 1530 | 1660 | 1660 | 1900 | |
| Peso neto (KG) | 45 | 62 | 85 | 95 | 125 | 152 | 175 | 185 | 215 | 283 | 345 | 382 | 580 | |
| Nota: Las especificaciones anteriores se ajustan a las siguientes condiciones de diseño: 1, 12℃/7℃. Temperatura de entrada/salida de agua fría 12℃/7℃. 2, 33℃/38℃. Temperatura de entrada/salida del aire de refrigeración 33℃/38℃. Nos reservamos el derecho de modificar las especificaciones sin previo aviso. | ||||||||||||||
Industrial Air Cooled Chiller Technical Specifications
| Elementos\Modelo | AC-15AT | AC-20AD | AC-20AF | AC-25AD | AC-25AF | AC-30AD | AC-30AT | AC-40AD | AC-40AF | AC-50AD | AC-50AF | AC-60AD | |
| Capacidad de refrigeración | kcal/h 50 Hz/60 Hz | 36120 | 49966 | 47988 | 58480 | 58136 | 74734 | 74922 | 98040 | 99760 | 119024 | 116960 | 144996 |
| 43344 | 59959 | 57586 | 70176 | 69763 | 89681 | 89990 | 117648 | 119712 | 142829 | 140352 | 173995 | ||
| KW 50 Hz/60 Hz | 42 | 58.1 | 55.8 | 68 | 67.6 | 86.9 | 87.2 | 114 | 116 | 138.4 | 136 | 168.6 | |
| 50.4 | 69.72 | 66.96 | 81.6 | 81.12 | 104.28 | 104.64 | 136.8 | 139.2 | 166.08 | 163.2 | 202.3 | ||
| Potencia de entrada | KW | 17.1 | 21.73 | 22 | 25.4 | 24.8 | 33.39 | 33.1 | 44.91 | 43.3 | 57.3 | 54 | 65 |
| Corriente máxima | A | 43.2 | 52.7 | 53.3 | 63.7 | 61.3 | 81 | 80.2 | 109 | 106 | 135.5 | 128.5 | 135 |
| Fuente de alimentación | 3PH~380V/415V/480V~50HZ/60HZ(3PH~200V/220V 50HZ/60HZ) | ||||||||||||
| Refrigerante | Tipo | R22/R407C/134a/404A/410A | |||||||||||
| Control | Válvula de expansión capilar/termostática | ||||||||||||
| Compresor | Tipo | Enrollador hermético (pistón) | |||||||||||
| Potencia (kW) | 4.55×3 | 8.96×2 | 4.55×4 | 10.8×2 | 5.25×4 | 13.62×2 | 8.96×3 | 18.78×2 | 8.96×4 | 23.6×2 | 10.8×4 | 27.4×2 | |
| Condensador | Tipo | Tubo de cobre con aletas de alta eficiencia y ventilador de rotor externo de aluminio y bajo nivel de ruido. | |||||||||||
| Caudal de aire (m³/h) | 15000 | 20000 | 20000 | 25000 | 25000 | 30000 | 30000 | 40000 | 40000 | 50000 | 50000 | 60000 | |
| Soplador de aire (KW) | 0.6×2 | 0.78×2 | 0.78×2 | 0.78×2 | 0.78×2 | 0.42×6 | 0.42×6 | 0.6×6 | 0.6×6 | 0.78×6 | 0.78×6 | 0.78×6 | |
| Evaporador | Tipo | Serpentín de acero inoxidable / Intercambiador de calor de carcasa y tubos / Intercambiador de calor de placas | |||||||||||
| Agua fría (m³/h) | 7.22 | 10 | 9.6 | 11.69 | 11.62 | 14.94 | 15 | 19.6 | 19.95 | 23.8 | 23.4 | 29 | |
| 8.67 | 11.99 | 11.51 | 14.03 | 13.95 | 17.93 | 18 | 23.52 | 23.94 | 28.6 | 28.1 | 34.8 | ||
| depósito de agua (L) | 270 | 350 | 350 | 350 | 350 | 420 | 420 | 580 | 580 | 580 | 580 | 580 | |
| tubo de entrada/salida (pulgada) | 2″ | 2″ | 2″ | 2-1/2″ | 2-1/2″ | 2-1/2″ | 2-1/2″ | 3″ | 3″ | 3″ | 3″ | 3″ | |
| Bomba de agua | Potencia (kW) | 2.2 | 2.2 | 2.2 | 2.2 | 2.2 | 4 | 4 | 4 | 4 | 5.5 | 5.5 | 5.5 |
| Elevación máxima (m) | 28 | 28 | 28 | 28 | 28 | 30 | 30 | 30 | 30 | 32 | 32 | 32 | |
| Caudal máximo (m³) | 25.2 | 25.2 | 25.2 | 25.2 | 25.2 | 36 | 36 | 36 | 36 | 40 | 40 | 40 | |
| Dispositivos de seguridad | Protección interna del compresor, protección contra sobrecorriente, protección contra alta/baja presión, protección contra sobretemperatura, protección de caudal, protección contra secuencia de fases/falta de fase, protección contra bajo nivel de refrigerante, protección anticongelante, protección contra sobrecalentamiento del escape. | ||||||||||||
| Dimensión | L (mm) | 1860 | 2020 | 2020 | 2020 | 2020 | 2200 | 2200 | 2350 | 2350 | 2600 | 2600 | 2600 |
| Ancho (mm) | 850 | 950 | 950 | 950 | 950 | 1150 | 1150 | 1350 | 1350 | 1500 | 1500 | 1500 | |
| Mmm) | 1900 | 2000 | 2000 | 2000 | 2000 | 1980 | 1980 | 2000 | 2000 | 2100 | 2100 | 2100 | |
| Peso neto (KG) | 580 | 650 | 650 | 810 | 810 | 890 | 890 | 1112 | 1112 | 1320 | 1320 | 1320 | |
| Nota: Las especificaciones anteriores se ajustan a las siguientes condiciones de diseño: 1. Temperatura de entrada/salida del agua fría: 12℃/7℃. 2. Temperatura de entrada/salida del aire de refrigeración: 33℃/38℃. Nos reservamos el derecho de modificar las especificaciones sin previo aviso. | |||||||||||||
| Modelo | 180Z | 250Z | 320Z | 430Z | 500Z | 570Z | 640Z | 760Z | 870Z | 930Z | 1000Z | 1180Z | 1260Z | 1500Z | 1730Z | |
| Capacidad de refrigeración * | kW | 184.9 | 247.6 | 315.6 | 432.5 | 495.6 | 563.2 | 631.2 | 752.4 | 865 | 928.1 | 991.2 | 1180.6 | 1262.4 | 1496.2 | 1730 |
| Potencia de entrada* | kW | 58.4 | 73.4 | 97.2 | 125.1 | 154.2 | 170.6 | 194.4 | 222.3 | 250.1 | 279.2 | 308.3 | 347.3 | 388.8 | 444.5 | 500 |
| Fuente de alimentación | 380-460V/3PH/50-60Hz | |||||||||||||||
| Max working current | A | 107.9 | 134.6 | 178.9 | 228.8 | 282.5 | 313.6 | 357.9 | 407.7 | 457.3 | 511.1 | 564.8 | 636.3 | 715.7 | 815.2 | 914.3 |
| Max starting current | A | 619.9 | 729.9 | 907.3 | 1089.3 | 1459.7 | 1001.2 | 1041.9 | 1268.2 | 1324.5 | 1688.5 | 1735.8 | 1402.9 | 1444.1 | 1497 | 1775.5 |
| Compresor | ||||||||||||||||
| Tipo | Tornillo semihermético | |||||||||||||||
| Cantidad/circuito de refrigerante | N.º. | 1/1 | 1/1 | 1/1 | 1/1 | 1/1 | 2/2 | 2/2 | 2/2 | 2/2 | 2/2 | 2/2 | 3/3 | 3/3 | 4/4 | 4/4 |
| Ajuste de energía | \ | 25%~100% for single compressor | ||||||||||||||
| Refrigerante | ||||||||||||||||
| Tipo | R407C/R22/R134a/R410a | |||||||||||||||
| Standard type | kg | 48 | 60 | 100 | 130 | 152 | 60+100 | 2×100 | 100+130 | 2×130 | 130+152 | 2×152 | 100+2×130 | 3×130 | 2×100+2×130 | 4×130 |
| Control | \ | External balanced expansion valve | External balanced expansion valve | |||||||||||||
| Axial Fan | ||||||||||||||||
| Cantidad de ventiladores | N.º. | 4 | 4 | 6 | 6 | 8 | 10 | 12 | 12 | 12 | 14 | 16 | 18 | 18 | 24 | 24 |
| flujo de aire | m3/h | 96000 | 96000 | 144000 | 144000 | 192000 | 240000 | 288000 | 288000 | 288000 | 336000 | 384000 | 432000 | 432000 | 576000 | 576000 |
| Evaporador | ||||||||||||||||
| Caudal de agua | m3/h | 31.8 | 42.6 | 54.3 | 74.4 | 85.2 | 96.9 | 108.5 | 129.4 | 148.8 | 159.6 | 170.5 | 203 | 217.1 | 257.3 | 297.5 |
| Caída de presión en el lado del agua | kPa | 41 | 42 | 42 | 42 | 42 | 43 | 43 | 44 | 45 | 45 | 43 | 43 | 42 | 43 | 43 |
| Tamaño de la tubería | DN | 80 | 80 | 100 | 125 | 125 | 125 | 125 | 125 | 150 | 150 | 150 | 100 150 | 125 150 | 125 150 | 150 |
| Dimensiones | ||||||||||||||||
| Longitud | mm | 2636 | 2636 | 3426 | 3726 | 5270 | 6060 | 6850 | 7150 | 7450 | 8994 | 10538 | 10874 | 11174 | 14594 | 15194 |
| Ancho | mm | 2160 | 2160 | 2160 | 2160 | 2160 | 2160 | 2160 | 2160 | 2160 | 2160 | 2160 | 2160 | 2160 | 2160 | 2160 |
| Altura | mm | 2430 | 2430 | 2430 | 2430 | 2430 | 2430 | 2430 | 2430 | 2430 | 2610 | 2610 | 2610 | 2610 | 2610 | 2610 |
| Peso neto | kg | 2050 | 2350 | 2750 | 3150 | 3850 | 4800 | 5250 | 5600 | 6150 | 6900 | 7600 | 9050 | 11000 | 11800 | 12600 |
| Sound pressure level ** | dB(A) | 76 | 76 | 77 | 77 | 78 | 80 | 81 | 81 | 81 | 82 | 83 | 84 | 84 | 84 | 84 |
| * The performance values refer to the following conditions: Cooling: ambient air temperature 35ºC; evaporator water in/out temperature 12/7 ºC; ** Sound pressure measured at a distance of 1 m and a height of 1.5 m above the ground in a dear field. | ||||||||||||||||
Portuguese Automotive Parts Factory

A certain automotive parts factory in Portugal had a sudden malfunction of the cooling unit, causing the production line to be at risk of shutdown. Chillerone promptly provided a 100-ton industrial air-cooled chiller, which did not require a cooling tower and could be directly connected to the original chilled water system. After the equipment arrived, it was quickly installed and debugged, and production was restored within a short period of time. The customer praised the chiller unit for its stable operation and the avoidance of long-term production downtime.
Turkish Textile Factory Expansion

A certain textile factory in Turkey added new production areas, but there was no space to install cooling towers in the factory. Chillerone configured an 80-ton industrial air-cooled water chiller as an independent cooling source to supply cooling for the new line. This solution did not require the renovation of the original cooling water system and also eliminated the need for cooling towers and pipeline construction. The new area was successfully put into production, and the customer believed that air-cooled chillers were more flexible for installation in expansion projects.
Vietnamese Electronic Assembly Factory

A certain electronic assembly factory in Vietnam had multiple devices each equipped with a cooling device, resulting in scattered management and inconsistent water temperatures. Chillerone provided a 120-ton air-cooled chiller system, consisting of 2 60-ton units, to supply cooling to various production areas through a centralized chilled water loop. After the system was put into use, the cooling management became more unified, and single units could be flexibly activated under partial load. The customer recognized the overall cooling stability of the air-cooled chillers.
United Arab Emirates Tobacco Factory Renovation

The original cooling system of a certain tobacco factory in the United Arab Emirates was aging, and the local summer environment temperature was high, making maintenance difficult. Chillerone delivered 2 150-ton industrial air-cooled chillers, with a total cooling capacity of 300 tons, installed outdoors. The equipment operated continuously in the high-temperature environment without the need for additional cooling towers. After the cooling system upgrade was completed, the cooling reliability of the factory was improved, and the customer believed that this solution was suitable for the renovation of old factories in high-temperature areas.
See the Industrial Air Cooled Chiller in Action
Watch how the industrial air cooled chiller delivers stable temperature control, fast cooling response, and reliable performance in real industrial working conditions.
What Is An Industrial Air Cooled Chiller?
ChillerOne industrial air cooled chillers are a type of circulating equipment that uses fans to drive ambient air and force it to blow over heat exchange coils with fins, thereby removing the heat of the industrial equipment’s hot fluid circulating inside the tubes, which achieves efficient cooling.
It relies on air for heat dissipation, without the need to consume water resources or install cooling towers. It features easy installation and simple maintenance, and is widely used in numerous industrial fields such as injection molding and laser, providing stable and reliable temperature control for your equipment.
The Working Principle of Industrial Air Cooled Chillers
- Paso 1: The hot process fluid that needs to be cooled flows into the heat exchange coil inside the cooler under the drive of the pump.
- Paso 2: Start the fan and forcibly draw in a large amount of cold air from the environment, causing it to blow over the surface of the fins wrapped around the coil.
- Paso 3: The heat of the fluid inside the coil is conducted through the tube wall to the highly thermally conductive fins. The fins greatly increase their contact area with the air, thereby efficiently releasing heat into the cold air flowing through them.
- Paso 4: After the heat exchange is completed, the hot air with increased temperature is discharged into the surrounding atmosphere by the fan. Meanwhile, the fluid that has lost heat in the coil cools down and turns into a cooled fluid.
- Paso 5: The cooled fluid flows out from the cooler outlet and is transported back to the industrial equipment you need to cool. After absorbing the heat it generates, it turns back into a hot fluid and begins the next cycle.
Features of Industrial Air Cooled Chillers
Air Cooling
Our industrial air cooled chillers fully utilize ambient air as the cooling medium. It forces in the cold air from the environment through a high-power fan, allowing it to flow over the surface of the heat exchanger to carry away the heat of the process fluid. It does not rely on water resources at all, which avoids the evaporation loss of cooling towers and water treatment issues.
Finned Tube Heat Exchange Design
ChillerOne industrial air cooled chiller adopts a highly efficient finned tube heat exchanger. By adding a large number of fins to the outer wall of the fluid pipeline, it greatly increases the contact heat dissipation area with the air, which significantly enhances the heat exchange efficiency between the air and the fluid.
Closed Loop System
Our industrial air cooled chillers, together with your cooled equipment, form a closed circulation system. The cooling fluid circulates within the system and does not cross-contaminate the external environment. This not only effectively prevents pipe scaling and clogging, but also greatly reduces fluid consumption and maintenance frequency.
Fácil de instalar
Industrial air cooled chillers do not require external facilities such as cooling towers, so their installation process is very simple. You usually only need to connect the inlet and outlet pipes and the power supply to put it into operation. This feature enables it to be flexibly installed in any well-ventilated place such as rooftops, platforms or floors, without occupying your indoor production space.
Fiabilidad
Our industrial air cooled chillers are generally equipped with intelligent control systems, which can monitor and precisely control the fluid temperature, pressure and equipment operation status in real time. Meanwhile, our system is equipped with multiple automatic protection functions to ensure the reliability and safety of its operation.
Advantages of Using Industrial Air Cooled Chillers
Save Costs
enfriadores refrigerados por aire fully utilize air for heat dissipation and do not consume water resources. This not only directly saves water bills, but also eliminates the cost of installing cooling towers and regular maintenance expenses.
Operación continua
The core components of ChillerOne industrial air cooled chillers, such as compressors and fan motors, are all industrial grade, which feature extremely high durability. It monitors the operation status in real time through an intelligent control system, effectively preventing your production line from malfunctioning and ensuring continuous and stable operation for 7×24 hours without interruption.
Low Power Consumption
The compressor and water pump can automatically adjust the output power according to the actual heat load, avoiding energy waste. At the same time, since it does not consume as much additional electricity as water-cooling systems to drive cooling towers and water treatment equipment, its comprehensive energy consumption during long-term operation is lower.
Mantenimiento sencillo
The maintenance of our industrial air cooled chillers is extremely simple and straightforward. You only need to regularly clean the dust and debris on the surface of the finned condenser to ensure smooth ventilation. It eliminates the complex water treatment work in water cooling systems, and also avoids performance degradation and system failures caused by scale and corrosion, which significantly reduces the complexity and frequency of your maintenance.
ChillerOne — Your Leading Supplier of Chiller Equipment
As a well-known domestic manufacturer and supplier of water chillers, ChillerOne designs various types of water chillers and can customize different process water chillers according to your specific needs.
This article introduces our industrial air-cooled chiller from multiple dimensions. It can precisely cool your equipment without taking up much space, ensuring the smooth progress of your project while significantly saving you costs. If you plan to purchase an industrial air-cooled cooler, ChillerOne is your ideal choice.
If you have any further questions about the cooler, please feel free to contact us at any time. We will ensure that your procurement process is economical, efficient and compliant, providing support for your business development.
Air cooled chillers do not require cooling towers or water sources. They are easy to install and maintain, and have a lower total holding cost. They are an ideal choice for customers in water-scarce areas and with limited space. However, water cooled chillers have slightly higher energy efficiency in applications with constant full-load operation and abundant water sources for ultra-large cooling capacity.
For high-temperature environments, we offer large-sized condensers and high-temperature dedicated models to ensure that the cooling capacity does not decline. For dusty environments, we can select dust-proof filters to protect the condenser fins and ensure the long-term stable operation of your equipment.
Sure. Our industrial air cooled chillers are equipped with standard intelligent communication interfaces, which can be easily integrated into your factory management system. You can achieve remote start and stop, temperature setting, fault monitoring and energy consumption data collection to realize intelligent management.
Sure. Our product itself offers modular models. In the future, you can increase the cooling capacity by combining them in parallel. In addition, our control system reserves expansion interfaces and capacity to ensure seamless integration with the existing system after adding new modules.
We have kept the operating noise of the equipment at the leading level in the industry by adopting low-noise fans and optimizing the air duct design. Meanwhile, we support you in choosing soundproof enclosures and noise reduction installation solutions, which can further reduce the impact of noise according to the layout of your workshop.